1
Hi, Guest!

  LOKASI :  Jakarta Barat

  AKTIVITAS :  18/10/2019

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus [email protected] !
F L O W M E T E R S P U M P & S A F E T Y T O O L S

LightScout Quantum Meters

Update Terakhir
:
30 / 08 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
PT. DAYA TEKNIK METERINDO
HARCO GLODOK Lantai 5 Blok F7
Jl. Hayam Wuruk No.2-5, Jakarta Barat 11180
Telp. : 021-2268 7062,
HP : 0813 1516 6062; 0813 1461 3990
Email: [email protected]
Up : Irwan Pangaribuan

Detail LightScout Quantum Meters

LightScout Quantum Meters Specifications 3415F Accuracy The Field Scout Light Meters are accurate to ± 5% . Cosine correction is accurate to ± 3% at 45° , and ± 7% at 80° . Quantum Light Meters are calibrated to display PPFD. The meters display PPFD in the range 0-1999 µ mol m-2 s-1. 3415FSE and 3415FXSE Accuracy The Field Scout Light Meters are accurate to ± 5% . Cosine correction is accurate to ± 3% at 45° , and ± 7% at 80° . 3415FQF Accuracy The Field Scout Light Meters are accurate to ± 5% . Cosine correction is accurate to ± 3% at 45° , and ± 7% at 80° . The 3415FQF Quantum and Foot-Candle Meter measures both PAR light, and light intensity as perceived by the human eye. The eye perceives light of approximately 560 nm most strongly, with perception half that at 500 and 600 nm. The meters display values in the range 0-1999. This must be multiplied by 10 to obtain Foot-Candles, so the meter range is 0-19990 Foot-Candles. Since 1 Foot-Candle is equivalent to approximately 10.8 lux, multiplying the meter reading by 108.
Tampilkan Lebih Banyak
pt. daya teknik meterindo
pt. daya teknik meterindo

PT. DAYA TEKNIK METERINDO

PREMIUM GOLD 7 Tahun
PT. DAYA TEKNIK METERINDO
Gedung HARCO GLODOK Lantai 5 Blok F7.
Jl. Hayam Wuruk No. 2-5, Jakarta Barat 11180.
Telp. : 021-2268 7062,
HP : 0813 1516 6062; 0813 1461 3990
Email: [email protected] , Jakarta Barat
Indonesia 11180
Jakarta Barat
18 / 10 / 2019
Hubungi Kami

Detail LightScout Quantum Meters

LightScout Quantum Meters Specifications 3415F Accuracy The Field Scout Light Meters are accurate to ± 5% . Cosine correction is accurate to ± 3% at 45° , and ± 7% at 80° . Quantum Light Meters are calibrated to display PPFD. The meters display PPFD in the range 0-1999 µ mol m-2 s-1. 3415FSE and 3415FXSE Accuracy The Field Scout Light Meters are accurate to ± 5% . Cosine correction is accurate to ± 3% at 45° , and ± 7% at 80° . 3415FQF Accuracy The Field Scout Light Meters are accurate to ± 5% . Cosine correction is accurate to ± 3% at 45° , and ± 7% at 80° . The 3415FQF Quantum and Foot-Candle Meter measures both PAR light, and light intensity as perceived by the human eye. The eye perceives light of approximately 560 nm most strongly, with perception half that at 500 and 600 nm. The meters display values in the range 0-1999. This must be multiplied by 10 to obtain Foot-Candles, so the meter range is 0-19990 Foot-Candles. Since 1 Foot-Candle is equivalent to approximately 10.8 lux, multiplying the meter reading by 108.
Tampilkan Lebih Banyak