Metrological Characteristics
Typical Performance
Nominal diameter ( DN) : 400mm
16"
Starting flowrate ( m3/ h) : 15
Accuracy ± 2% from* ( m3/ h) : 30
Accuracy ± 5% from* ( m3/ h) : 25
Admissible peak flow ( 10’ max) ( m3/ h) : 4500
Max. admissible flowrate ( continuous) ( m3/ h) : 3000
Head loss at Qmax ( bar) : 0.17
Max. admissible temperature ( ° C) : 50
Max. admissible pressure ( bar) : 20
Min. scale interval ( L) : 20
Indicating range ( m3) : 99999999
Cyble HF pulse weight ( L) : 1000
EEC Approval Values
Nominal diameter ( DN) : 400mm ( 16" )
EEC/ ISO class approval : Class B all positions
Nominal flow rate Qn ( m3/ h)
G : 1500
N : 1000
Max. flow rate Qmax ( m3/ h)
G : 3000
N : 2000
Accuracy ± 2% class B: Qt from ( m3/ h)
G : 300
N : 200
Accuracy ± 5% class B: Qmin from m3/ h
G : 45
N : 30
Max. temperature ( ° C) : 30