Detail ITRON FLOWMETER DN 50 6 ( 150MM)
ITRON FLOWMETER DN 50 6" ( 150MM)
Water Meter
Itron DN 50 ( 2" )
Metrological Characteristics
Typical Performance
Nominal diameter ( DN) : 150mm
6"
Starting flowrate ( m3/ h) : 1
Accuracy ± 2% from* ( m3/ h) : 3
Accuracy ± 5% from* ( m3/ h) : 1.5
Admissible peak flow ( 10’ max) ( m3/ h) : 700
Max. admissible flowrate ( continuous) ( m3/ h) : 500
Head loss at Qmax ( bar) : 0.15
Max. admissible temperature ( ° C) : 50
Max. admissible pressure ( bar) : 20
Min. scale interval ( L) : 20
Indicating range ( m3) : 99999999
Cyble HF pulse weight ( L) : 1000
EEC Approval Values
Nominal diameter ( DN) : 150mm ( 6" )
EEC/ ISO class approval : Class B all positions
Nominal flow rate Qn ( m3/ h)
G : 250
N : 150
Max. flow rate Qmax ( m3/ h)
G : 500
N : 300
Accuracy ± 2% class B: Qt from ( m3/ h)
G : 50
N : 30
Accuracy ± 5% class B: Qmin from m3/ h
G : 7.5
N : 4.5
Max. temperature ( ° C) : 30
EEC approval certificate : F-02-G071